Product Details:

  • Voltage Not required (mechanical device)
  • Fire Class Class A & B
  • Installation Type Inline Horizontal
  • Shape Cylindrical
  • Operating Pressure Up to 12 bar
  • Technology Venturi Principle
  • Mounting Type Inline mount
X

Inline Foam Generator Product Specifications

  • Fire Fighting Foam Systems
  • 0C to 49C
  • Up to 12 bar
  • 63 mm
  • Venturi Principle
  • Red
  • Corrosion-resistant, Low maintenance, High mixing efficiency
  • Inline mount
  • 7 bar
  • Varies by system
  • Inline Foam Generator
  • Fire Fighting
  • Not required (mechanical device)
  • 450 LPM
  • Foam-based
  • Class A & B
  • Inline Horizontal
  • Automatic
  • Flanged or threaded ends
  • Epoxy coated
  • Depends on system design
  • Cylindrical
  • IS 12469 / UL Listed (as applicable)
  • Typically 3% or 6%
  • Stainless Steel / Mild Steel
  • AFFF, Protein or Synthetic foams
  • 10+ years under normal conditions
  • Flanged as per ANSI / DIN standards
  • Depends on diameter and model (approx. 6 kg to 35 kg)
  • Flush with water after use

Inline Foam Generator Trade Information

  • All India

Product Description

We offer our clients the qualitative range of Inline Foam Generator that is used in fire stations and in the construction industry. This foam generator is well known for rugged construction, hassle free performance, reliability and easy installation. At our sound production unit, we manufacture this Inline Foam Generator using premium quality steel. The foam generator comes with smoke extracting system and duct. In order to ensure the optimum quality, the offered foam generator is stringently tested by our experienced quality controllers against numerous parameters.

Salient Features :

  • Inline Foam Generator is modified version of Inline Inductor, which not only inducts the foam in desired concentration 3% or 6%, but also transports the foam a long distance (approx. 60 mtrs)
  • Inlet - British Standard Instantaneous Couplings
  • Outlet - British Standard Instantaneous Coupling
  • Induction - 3 % or 6 %

Specification :

Item Code

Flow @ 7 bar

Material of Construction

FE-FGI

225 LPM, 450 LPM

Aluminum Alloy Gunmetal



Advanced Fire Suppression Technology

Utilizing the Venturi principle, the Inline Foam Generator efficiently mixes foam concentrate with water, delivering reliable fire-suppressing foam for various risk scenarios. Its cylindrical, corrosion-resistant design ensures consistent performance and durability, making it ideal for industrial, commercial, or public fire protection systems.


Flexible Installation and Compatibility

This foam generator offers easy integration into inline horizontal piping, with flanged or threaded connections in compliance with ANSI and DIN standards. Its design accommodates various foam types-AFFF, protein, or synthetic-making it adaptable for multiple fire-fighting environments. Maintenance is simple, further supporting its broad utility.

FAQ's of Inline Foam Generator:


Q: How does the Inline Foam Generator operate in a fire fighting system?

A: The Inline Foam Generator works on the Venturi principle, automatically mixing foam concentrate with water as it passes through the device. This process generates an effective foam solution for extinguishing Class A and B fires in fire fighting systems.

Q: What materials and construction standards are used in this foam generator?

A: The device is built from high-quality stainless steel or mild steel and features an epoxy coating for corrosion resistance. It adheres to international end connection standards such as ANSI and DIN, ensuring reliable integration and durability.

Q: When should the Inline Foam Generator be cleaned or maintained?

A: After each use, it is recommended to flush the generator with water to remove any foam residue. Routine inspection should be performed as per fire safety protocols to ensure optimal performance and extend its service life beyond 10 years under normal operating conditions.

Q: Where can this foam generator be installed within a fire fighting system?

A: It is specifically designed for inline horizontal installation in foam-based fire fighting systems. The generator can be mounted directly into the piping network with flanged or threaded connections, as required by the system's layout.

Q: What types of foams are recommended for use in this generator?

A: The Inline Foam Generator is compatible with AFFF (Aqueous Film Forming Foam), protein-based, and synthetic foams. This flexibility allows it to address various fire risks effectively.

Q: What are the benefits of using this foam generator in fire systems?

A: Key benefits include high mixing efficiency, automatic operation, corrosion resistance, low maintenance requirements, and compliance with major approval standards such as IS 12469 and UL Listed, ensuring reliable fire protection and long operating life.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Foam Equipments' category