Call Us
Call Us
08045800044
Change Language
NEWAGE HYDRANT VALVE SS

Product Details:

  • Technology Single Outlet Hydrant Valve, Conventional Design
  • Working Temperature -10C to +55C
  • Control Type Hand Wheel Operated
  • Fire Class Class A, B, and C Fires
  • Fire Extinguisher Type Fire Hydrant Valve; Wet Barrel
  • Coating Type Mirror Polished Finish
  • Coverage Area Depends on hose length and nozzle attached
4500 INR/Piece
X

NEWAGE HYDRANT VALVE SS Price And Quantity

  • 1 Piece
  • 4500 INR/Piece

NEWAGE HYDRANT VALVE SS Product Specifications

  • -10C to +55C
  • Hand Wheel Operated
  • Single Outlet Hydrant Valve, Conventional Design
  • Tested up to 21 kg/cm2
  • Hydraulic - as per hose and pressure
  • Corrosion Resistant, Sturdy Construction, High Flow, Leakproof
  • Flanged/Wall Mounted
  • Flanged Inlet, Female Coupling Outlet
  • Right Angle (L-type)
  • Up to 900 L/min
  • Up to 14 kg/cm2 (working)
  • Depends on hose length and nozzle attached
  • Firefighting, Industrial, Commercial Buildings, Marine
  • Wall Mounted, Surface Mounted
  • 63 mm (2.5 inches)
  • Mirror Polished Finish
  • Fire Hydrant Valve; Wet Barrel
  • Class A, B, and C Fires
  • Stainless Steel (SS 304/SS 316 grade)
  • Natural steel or red epoxy painted (optional)
  • 63 mm female instantaneous coupling
  • Aluminium alloy
  • ISI Marked, conforming to IS:5290 Type A
  • Rubber washer
  • Neoprene rubber
  • Polished stainless steel
  • Approximately 6-7 kg
  • Excellent due to stainless steel construction
  • Flanged (75 mm standard)
  • Flanged to BS 10 Table D/E/F or IS standard

NEWAGE HYDRANT VALVE SS Trade Information

  • Cash on Delivery (COD)
  • All India

Product Description

Hydrant Valve Specifications :-

Outlet- 63mm Female coupling with spring lock type Lug as per IS: 5290 Type A.

Flange Size - O.D. 200mm, PCD 160mm, 4 Holes Dia. 19mm
Material of Construction : SS 304



Durable Stainless Steel Construction

Crafted from SS 304 or SS 316 stainless steel, the NEWAGE Hydrant Valve is built to last in tough environments. Its resistance to corrosion, combined with a polished or optional red epoxy finish, ensures long-term reliability, even in industrial or marine settings prone to harsh conditions. This makes the hydrant valve an excellent choice for facilities demanding both strength and longevity.


Engineered for Safety and Compliance

This hydrant valve adheres to stringent ISI Marked standards and conforms to IS:5290 Type A, ensuring it meets rigorous quality and safety benchmarks. Each unit undergoes pressure testing up to 21 kg/cm2 and maintains a working pressure of up to 14 kg/cm2, guaranteeing dependable performance during emergencies and peace of mind for operators and property owners.


User-Friendly Operation and Installation

Designed with a handwheel mechanism and a flanged inlet/outlet, the valve is simple to operate for first responders and easy to install on walls or surfaces. Its compatibility with standard couplings and mounting configurations allows for efficient setup and integration into a variety of fire safety systems. The sleek finish also supports ease of maintenance and visual inspection.

FAQ's of NEWAGE HYDRANT VALVE SS:


Q: How do I install the NEWAGE Hydrant Valve SS in my facility?

A: Installation is straightforward-mount the valve onto a suitable wall or surface using the flanged inlet (75 mm) and ensure it matches the BS 10 Table D/E/F or IS standard bolting pattern. Proper alignment with your firewater pipeline and secure attachment are important for optimal performance.

Q: What are the benefits of choosing a stainless steel (SS 304/316) hydrant valve?

A: Stainless steel construction offers outstanding corrosion resistance, strength, and reliability. This is essential for long-term use, especially in industrial, marine, or outdoor locations where exposure to moisture and chemicals is common.

Q: Where is the hydrant valve typically used?

A: The NEWAGE Hydrant Valve SS is ideal for installation in firefighting systems for industrial complexes, commercial buildings, and marine environments. Its robust, leakproof design ensures reliable operation during emergency fire suppression.

Q: What process should I follow to operate the valve during a fire emergency?

A: To operate, attach the hose to the 63 mm female instantaneous coupling outlet and turn the handwheel to release water. The valve's single outlet, high-flow design supports rapid deployment for fire suppression across Class A, B, and C fire hazards.

Q: When should the hydrant valve be maintained?

A: Routine inspection and maintenance should be scheduled at least semi-annually. Check the handwheel, seals, coupling connections, and the mirror-polished surface for signs of leakage, wear, or corrosion to ensure reliability during emergencies.

Q: What is the maximum flow rate and working pressure of this hydrant valve?

A: The valve delivers up to 900 liters per minute under optimal conditions and is designed to work safely at pressures up to 14 kg/cm2, with pressure testing conducted at 21 kg/cm2 for added safety assurance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Hydrant Accessories' category