Product Description
By keeping track of the latest market developments, we are involved in offering Double Headed Hydrant Valve. This hydrant valve is generally demanded in commercial, residential and industrial sector to control the flow of fire hydrants in an efficient manner. In addition to this, compact design, easy installation, robust construction, corrosion and high pressure resistance are features of offered hydrant valve. Available in various specifications, this Double Headed Hydrant Valve can be bought from us at nominal prices.
Salient Features :
- Double Headed Hydrant Valve are designed and manufactured as per IS:5290-1993
- Highly Durable and Corrosion Resistant
- Excellent Flow Characteristics
Specification :
- Item Code : HV-DHV-GM ,HV-DHV -SS
- Size : 2 1/2
- Inlet : 4 Flanged
- Outlet : 2 1/2 Female Instantaneous
- Test Pressure :300 PSI
- Material of Construction :Gunmetal Stainless Steel
Robust Firefighting PerformanceWith a capacity to deliver up to 900 LPM and withstand operating pressures up to 16 bar, the Double Headed Hydrant Valve ensures swift water delivery for tackling Class A, B, and C fires. Its dual outlets allow simultaneous operation, improving firefighting efficiency and coverage in critical scenarios.
Engineered for Reliability and DurabilityManufactured using high-quality metals, aluminum or brass handles, and finished with a red anti-corrosive powder coating, this hydrant valve is built to last. Leak-proof operation is accomplished by precision-fitted rubber washers and O-rings, ensuring trusted performance in diverse industrial and outdoor environments.
Simple Installation and OperationDesigned for both wall-mounted and ground-mounted installations, the valve's flanged base and robust mounting feature guarantee secure fitting. Manual wheel operation provides straightforward control without the need for electricity, making it suitable for emergency fire safety systems across various commercial sectors.
FAQ's of Double Headed Hydrant Valve:
Q: How do you operate the Double Headed Hydrant Valve?
A: To operate the Double Headed Hydrant Valve, turn the manual wheel (made from aluminum or brass) to open or close the water supply. Its dual outlets allow the simultaneous connection and operation of two hoses, facilitating efficient firefighting during emergencies.
Q: What are the main benefits of using a double outlet hydrant valve in fire safety systems?
A: The double outlet design enables two hoses to run at once, doubling the firefighting capacity. This ensures greater water coverage, faster response, and practical flexibility during extensive fire incidents-all in a robust, corrosion-resistant construction.
Q: When and where should this hydrant valve be installed?
A: Install this hydrant valve in fixed fire hydrant systems, either wall-mounted or ground-mounted, within industrial, commercial, or municipal environments. It is essential for settings where rapid water access is needed for tackling fires.
Q: What process should be followed for installing this hydrant valve?
A: The valve should be securely bolted to a fixed mount, aligning the 100 mm flanged inlet connection to the hydrant network. Ensure all seals (rubber washer & O-ring) are properly fitted for leak-proof operation. Finalize with hose connections to the 63 mm instant outlets.
Q: What level of fire protection coverage is provided by this valve?
A: Designed for high-flow rates up to 900 LPM and operating pressures up to 16 bar, the valve offers wide-area fire protection, effectively supporting fire suppression tasks in factories, warehouses, and public premises.
Q: What environmental conditions can the valve operate in?
A: This valve functions reliably within a temperature range of -10C to +60C and is protected by a red powder-coated, anti-corrosive finish, making it suitable for diverse Indian weather and industrial conditions.